The following symbols may be used on FUJIFILM Sonosite products, packageing, and containers. This list is comprehensive for all of our products. All products do not display all of the following symbols.

SymbolSymbol TitleSymbol DescriptionStandards Reference
Symbol for ManufacturerManufacturerIndicates the medical device manufacturer.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.1.1
Symbol for Date of manufactureDate of manufactureTo indicate the date on which a product was manufactured.ISO 7000- Graphical symbols for Use on Equipment 5.1.3
Symbol for Date of Catalog NumberCatalogue NumberIndicates the manufacturer’s catalogueue number so that the medical device can be identified.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.1.6
Symbol for Serial NumberSerial NumberIndicates the manufacturer’s serial number so that a specific medical device can be identified.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.1.7
Symbol for Batch code, date code, or lot code type of control numberBatch code, date code, or lot code type of control numberIndicates manufacturer's batch code so that the batch or lot can be identified.ISO 15223-1 Medical devices - Symbols to be used with medical device labels, labeling and information to be supplied - Part 1: General Requirements 5.1.5
Symbol for European community authorized representativeEuropean community authorised representativeIndicates the authorised representative in the European community.ISO 15223-1 Medical devices - symbols to be used with medical device labels, labeling and information to be supplied 5.1.2
Symbol for Conformité Européene Notified Body Reference No.: 2797Conformité Européene Notified Body Reference No.: 2797Indicates European technical conformity and identification of notified body responsible for implementation of the procedures set out in Annexes II, IV, V, and VI._
Symbol for CE markingCE markingSignifies European technical conformity._
Symbol for UK Conformity AssessedUK Conformity AssessedMark that indicates conformity with the applicable requirements for products sold within Great Britain.The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019.
Symbol for UK Conformity Assessed with Notified Body NumberUK Conformity Assessed with approved Body NumberMark, including the approved body number, that indicates conformity with the applicable requirements for products sold within Great Britain.The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019.
Symbol for Medical DeviceMedical DeviceIndicates the item the label is adhered to is categorized as a medical device per the MDR, Annex 1, 23.2, q.EU MDR EU MDR Annex I, 23.2 (q)
Symbol for UDIUDIUnique device identifier. This symbol is optional and is used when there are multiple data carriers on a label.ISO 15223-1:2021 5.7.10
Symbol for CautionCautionIndicates that caution is necessary when operating the device or control close to where the symbol is placed. 
Symbol for Refer to instruction manual/bookletRefer to instruction manual/bookletFollow instructions for use (used in accordance with IEC 60601-1).IEC 60601-1
Medical electrical equipment Part 1: General requirements for basic safety and essential performance D.2-10
Symbol for Consult instructions for useConsult instructions for useIndicates that the operating instructions should be considered when operating the device or control close to where the symbol is placed.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.4.3
Symbol for Recycle: Electronic EquipmentRecycle: Electronic EquipmentDo not throw in trash.BS EN 50419 Marking of Electrical and Electronic Equipment in accordance with Directive 2012/19/EU for the Waste of Electrical and Electronic Equipment (WEEE) and Directive 2006/66/EC on Batteries and Accumulators and Waste Batteries and Accumulators Annex IX
Symbol for Historic WEEEHistoric WEEEHistoric WEEE (trash can) without bar. No bar signifies products made before 2005._
Symbol for Electrostatic sensitive devicesElectrostatic sensitive devicesIndicates packages containing electrostatic sensitive devices, or identifies a device or a connector that has not been tested for immunity to electrostatic discharge.IEC 60417 Graphical Symbols For Use On Equipment 5134
Symbol for Caution hotCaution hotIndicates that the marked item can be hot and should not be touched without taking care.ISO 7000 / IEC 60417 Graphical symbols for use on equipment 5041
Symbol for ETL (electronic Testing Laboratories) certification markETL (electronic Testing Labouratories) certification markProof product complies to North American safety standards._
Symbol for UL Classified Canada and USUL Classified Canada and USCertification mark. 
Symbol for UL recognized component partUL recognised component partUL recognised component mark for Canada and the United States_
Symbol for Canadian Standard Association Certification MarkCanadian Standard Association Certification MarkCSA certification mark signifying that the product complies with the applicable CSA and ANSI/UL requirements and is authorised for use in Canada and the US._
Symbol for TUV Rhineland of North AmericaTUV Rhineland of North AmericaTUV Rhineland of North America. The “C” and US” indicators signify that the product has been evaluated to the applicable CSA and ANSI/UL standards for use in Canada and the US, respectively._
Symbol for TUV, SUD, Canada & USATUV, SUD, Canada & USATUV mark applied to labels where the product has been certified to Technischer Überwachungsverein. "C" demonstrates an electrical product has been successfully tested and certified by a Certification Body accredited by the Standards Council of Canada (SCC)._
Symbol for InMetro (Brazil) TUVInMetro (Brazil) TUVBrazilian equipment and electrical components approval_
Symbol for InMetro (Brazil) NCCInMetro (Brazil) NCCSignifies product has been assessed and certified to ABNT ISO/IEC 17065 and ABNT ISO / IEC 17021-1._
Symbol for China Compulsory Certificate mark ('CCC Mark')China Compulsory Certificate mark (“CCC Mark”)A compulsory safety mark for compliance to Chinese national standards for many products sold in the People’s Republic of China._
Symbol for China Pollution Control (10)China Pollution Control (10)Pollution Control Logo. (Applies to all parts/products listed in the China RoHS disclosure table. May not appear on the exterior of some parts/products because of space limitations.)ISO 7000: Graphical symbols for use on equipment 1135
Symbol for China RoHs, color-blackSymbol, China RoHs, colour-blackChina RoHs "e" indicates that the product contains less than the maximum concentration value of six hazardous substances._
Symbol for Regulatory Compliance Mark (RCM)Regulatory Compliance Mark (RCM)Indicates C-Tick-Regulatory Compliance Mark for Australia and New Zealand Device complies with relevant Australian and New Zealand regulations for electronic devices.AS/NZS3820
Symbol for Non-ionizing electromagnetic radiationNon-ionising electromagnetic radiationTo indicate generally elevated, potentially hazardous, levels of non-ionising radiation, or to indicate equipment or systems e.g. in the medical electrical area that include RF transmitters or that intentionally apply RF electromagnetic energy for diagnosis or treatment.IEC 60417
Symbol for Federal Communications Commission (FCC) Declaration of conformityFederal Communications Commission (FCC) Declaration of conformityFCC—Tested to Federal Communications Commission requirements. Device complies with relevant FCC regulations for electronic devices.Federal Communications Commission (FCC) Declaration of conformity 21 Part 15
Symbol for Magnetic resonance environment unsafeMagnetic resonance environment unsafeIndicates the system is an item that is known to pose hazards in all MR environments.ASTM International (American Society for Testing and Materials) ASTM F2503
Symbol for Degrees of Protection Provided by Enclosures (IP Code)Degrees of Protection Provided by Enclosures (IP Code).Protected against the effects of temporary immersion in water.IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance D.3-2
Symbol for Degrees of Protection Provided by Enclosures (IP Code)Degrees of Protection Provided by Enclosures (IP Code).Protected against solid objects over 12mm and direct sprays of water up to 15 degrees from the vertical.IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance D.3-2
Symbol for Temperature limitTemperature limitIndicates the temperature limits to which the medical device can be safely exposed.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.3.7
Symbol for Humidity limitationHumidity limitationIndicates the range of humidity to which the medical device can be safely exposed.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.3.8
Symbol for Atmospheric pressure limitationsAtmospheric pressure limitationsIndicates the range of atmospheric pressure to which the medical device can be safely exposed.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.3.9
Symbol for Fragile handle with careFragile handle with careIndicates a medical device that can be broken or damaged if not handled carefully.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.3.1
Symbol for Keep dryKeep dryIndicates a medical device that needs to be protected from moisture.ISO 15223-1 Medical devices – symbols to be used with medical device labels, labeling, and information to be supplied – Part 1: General requirements 5.3.4
Symbol for Corrugated recyclesCorrugated recyclesShipping box is made of corrugated cardboard and should be recycled accordingly._
Symbol for RESY – Recycling SymbolPaper recycle._
Symbol for Stacking limit by numberStacking limit by numberDo not stack over n high, where n represents the number on the label.ISO 7000 Graphical symbols for use on equipment
Symbol for Do not use if packaging is damagedDo not use if packageing is damagedDo not use product if the packageing has been damaged.ISO 7000-2606 ISO 15223-1, Clause 5.2.8
Symbol for Maximum weight loadMaximum weight loadIndicates total weight of the equipment, including the safe working load.IEC 60601-1 Medical Electrical Equipment Part 1: General requirements for basic safety and essential performance 7.2.21
Symbol for Potential equalization terminalPotential equalisation terminalIdentifies potential equalisation terminal.IEC 60601-1 Medical Electrical Equipment Part 1: General requirements\nfor basic safety and essential performance D.1-8
Symbol for Defibrillation-proof type CF applied partDefibrillation-proof type CF applied partIdentifies a defibrillation-proof type CF applied part complying with IEC 60601-1.IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance D.1-27
Symbol for Type BF applied partsType BF applied partsIdentifies type BF applied part complying with IEC 60601-1.IEC 60601-1 Medical Electrical Equipment Part 1: General requirements for basic safety and essential performance D.1-20
Symbol for Class II EquipmentClass II EquipmentTo identify equipment meeting the safety requirements specified for Class II equipment according to IEC 60536.IEC 60601, table D1-9
Symbol for Warning; Biological hazardWarning; Biological hazardTo warn of biological hazard.ISO 7010 - Graphical symbols -- Safety colours\nand safety signs W009
Symbol for Warning; Laser beamWarning; Laser beamTo warn of a laser beam.ISO 7010-W004
Symbol for Alternating currentAlternating currentIndicates on the rating plate, that the equipment is suitable for alternating current only, in order to identify appropriate terminals.IEC 60601-1
Medical electrical equipment
Symbol for Direct current (DC)Direct current (DC)To indicate on the rating plate that the equipment is suitable for direct current only; to identify relevant terminals.IEC 60601-1
Medical electrical equipment
Symbol for disinfecting timeN/AIndicates follow manufacturer’s instructions for disinfecting time._
Symbol for disinfect transducerN\/AIndicates disinfect transducer._
Symbol for handle with careN\/AIndicates handle with care._
Symbol for Caution, static magnetic field hazardCaution, static magnetic field hazardIdentifies areas with potentially hazardous static magnetic fields and forces in an instalation.IEC 60417-6204
Symbol for Power ButtonPower ButtonPower button symbol.-
Symbol ON (power)"ON" (power)To indicate connexion to the mains.ISO/IEC 13251
Symbol OFF (power)"OFF" (power)To indicate disconnexion from the mains.ISO/IEC 13251
Symbol ON/OFF (power)"ON" / "OFF"To indicate connexion to or disconnexion from the mains.IEC 62288
Symbol for General Prohibition SignGeneral Prohibition SignTo signify a prohibited action.ISO 20023
Symbol for No PushingNo pushingTo prohibit pushing against an object.ISO 24409-2:2014
Symbol for GelGel--
Symbol for Sterilized using irradiationSterilised using irradiationIndicates a medical device that has been sterilised using irradiation.ISO 15223-1 Medical devices - Symbols to be used with medical device labels, labeling and information to be supplied - Part 1: General Requirements 5.2.4
Symbol for Sterilized using ethylene oxideSterilised using ethylene oxideIndicates a medical device that has been sterilised using ethylene oxide.ISO 15223-1 Medical devices Symbols to be used with medical device labels, labeling and information to be supplied - Part 1: General Requirements\n5.2.3