TV Uterus with Migrating IUD Sagittal

TV Uterus with Migrating IUD Sagittal

/sites/default/files/TV_Uterus_with_Migrating_IUD_Sagittal.jpg
TV Uterus with Migrating IUD Sagittal
Clinical Specialties
Publication Date
Media Library Type

iViz 9: Cleaning and Disinfecting your iViz System

iViz 9: Cleaning and Disinfecting your iViz System

/sites/default/files/youtube_vKB5Ada5lFc.jpg
SW Revision
Clinical Specialties
Publication Date
Media Library Type
Subtitles
<p begin="00:00:00.543" end="00:00:03.626" style="s2">(light techno music)</p>
<p begin="00:00:08.868" end="00:00:12.118" style="s2">- [Voiceover] Welcome to the help video</p>
<p begin="00:00:14.251" end="00:00:15.377" style="s2">In this video,</p>
<p begin="00:00:15.377" end="00:00:18.190" style="s2">we will walk you though<br />cleaning and disinfecting</p>
<p begin="00:00:18.190" end="00:00:20.773" style="s2">both the system and transducer.</p>
<p begin="00:00:21.658" end="00:00:23.970" style="s2">Let's start with the system.</p>
<p begin="00:00:23.970" end="00:00:25.278" style="s2">Before cleaning,</p>
<p begin="00:00:25.278" end="00:00:28.291" style="s2">you want to make sure to<br />disconnect the transducer</p>
<p begin="00:00:28.291" end="00:00:30.291" style="s2">and turn off the system.</p>
<p begin="00:00:31.272" end="00:00:33.980" style="s2">Clean the exterior surfaces using either</p>
<p begin="00:00:33.980" end="00:00:37.046" style="s2">a soft cloth dampened with a disinfectant,</p>
<p begin="00:00:37.046" end="00:00:38.662" style="s2">or a pre-moistened wipe</p>
<p begin="00:00:38.662" end="00:00:40.916" style="s2">from the list of approved disinfectants</p>
<p begin="00:00:40.916" end="00:00:44.926" style="s2">to remove any particulate<br />matter or body fluids.</p>
<p begin="00:00:44.926" end="00:00:47.518" style="s2">Be sure to apply the solution to the cloth</p>
<p begin="00:00:47.518" end="00:00:50.438" style="s2">rather than applying it<br />directly to the surface</p>
<p begin="00:00:50.438" end="00:00:51.851" style="s2">making sure the solution</p>
<p begin="00:00:51.851" end="00:00:55.507" style="s2">does not get into the connector ports.</p>
<p begin="00:00:55.507" end="00:00:57.675" style="s2">Allow the system to air dry</p>
<p begin="00:00:57.675" end="00:01:01.697" style="s2">or dry it off with a soft, clean cloth.</p>
<p begin="00:01:01.697" end="00:01:05.670" style="s2">Next let's clean and<br />disinfect the transducer.</p>
<p begin="00:01:05.670" end="00:01:09.685" style="s2">Clean the transducer surface<br />using a damp, soft cloth</p>
<p begin="00:01:09.685" end="00:01:14.493" style="s2">to remove any gel, particulate<br />matter, and body fluids.</p>
<p begin="00:01:14.493" end="00:01:17.343" style="s2">Starting from the transducer's scan head,</p>
<p begin="00:01:17.343" end="00:01:20.926" style="s2">wipe in a downward<br />motion towards the cord.</p>
<p begin="00:01:23.032" end="00:01:25.680" style="s2">Once the transducer body is clean,</p>
<p begin="00:01:25.680" end="00:01:28.799" style="s2">use a thin instrument, such as a swab,</p>
<p begin="00:01:28.799" end="00:01:31.365" style="s2">to push the soft damp cleaning cloth</p>
<p begin="00:01:31.365" end="00:01:34.032" style="s2">back and forth through the slot.</p>
<p begin="00:01:40.365" end="00:01:43.596" style="s2">Then rinse or wipe the<br />transducer with water</p>
<p begin="00:01:43.596" end="00:01:46.263" style="s2">to remove the soap or detergent.</p>
<p begin="00:01:48.199" end="00:01:52.594" style="s2">To disinfect the transducer<br />using an approved disinfectant,</p>
<p begin="00:01:52.594" end="00:01:56.775" style="s2">disinfect the slot first<br />and then the transducer.</p>
<p begin="00:01:56.775" end="00:01:59.630" style="s2">If you use the immersion<br />method of disinfecting,</p>
<p begin="00:01:59.630" end="00:02:00.838" style="s2">be sure to follow</p>
<p begin="00:02:00.838" end="00:02:03.631" style="s2">the disinfectant<br />manufacturer's instructions</p>
<p begin="00:02:03.631" end="00:02:05.513" style="s2">and only immerse the transducer</p>
<p begin="00:02:05.513" end="00:02:08.430" style="s2">up to 12 inches from the connector.</p>
<p begin="00:02:09.281" end="00:02:11.669" style="s2">After cleaning and disinfecting,</p>
<p begin="00:02:11.669" end="00:02:16.129" style="s2">check the transducer and<br />cable for any visible damage.</p>
<p begin="00:02:16.129" end="00:02:18.177" style="s2">If you do see any damage,</p>
<p begin="00:02:18.177" end="00:02:22.344" style="s2">discontinue use and contact<br />Fujifilm Sonosite for service.</p>
<p begin="00:02:24.327" end="00:02:25.866" style="s2">For more detailed information</p>
<p begin="00:02:25.866" end="00:02:28.661" style="s2">on cleaning and disinfecting iViz,</p>
<p begin="00:02:28.661" end="00:02:31.661" style="s2">refer to the iViz system user guide.</p>
Brightcove ID
5508136014001
https://youtube.com/watch?v=vKB5Ada5lFc

iViz 8: Taking Measurements

iViz 8: Taking Measurements

/sites/default/files/youtube_8H8hEC6fLsk.jpg
SW Revision
Clinical Specialties
Publication Date
Media Library Type
Subtitles
<p begin="00:00:00.569" end="00:00:04.069" style="s2">(mellow electronic music)</p>
<p begin="00:00:08.981" end="00:00:12.601" style="s2">- [Voiceover] Welcome to the<br />help video Taking Measurements.</p>
<p begin="00:00:12.601" end="00:00:15.374" style="s2">In this video, we will<br />walk you through how to</p>
<p begin="00:00:15.374" end="00:00:20.082" style="s2">take a general measurement with<br />your iViz Ultrasound System.</p>
<p begin="00:00:20.082" end="00:00:22.832" style="s2">While scanning, freeze the image.</p>
<p begin="00:00:25.847" end="00:00:28.723" style="s2">Tap Measurements, and choose either</p>
<p begin="00:00:28.723" end="00:00:31.640" style="s2">the Distance or Volume measurement.</p>
<p begin="00:00:33.073" end="00:00:37.372" style="s2">Drag the active caliper to<br />the start of your measurement.</p>
<p begin="00:00:37.372" end="00:00:41.321" style="s2">Lift your finger to<br />activate the second caliper.</p>
<p begin="00:00:41.321" end="00:00:45.796" style="s2">Slide and place that<br />caliper at your end point.</p>
<p begin="00:00:45.796" end="00:00:50.526" style="s2">The measurement appears on the<br />top left side of the screen.</p>
<p begin="00:00:50.526" end="00:00:54.443" style="s2">To re-position a caliper,<br />just touch and slide.</p>
<p begin="00:00:55.754" end="00:00:59.497" style="s2">To add an additional caliper,<br />tap the measurement type</p>
<p begin="00:00:59.497" end="00:01:02.747" style="s2">and place those calipers on the screen.</p>
<p begin="00:01:04.308" end="00:01:08.494" style="s2">To delete a caliper, select<br />the caliper you want to delete</p>
<p begin="00:01:08.494" end="00:01:10.411" style="s2">and then tap the red X.</p>
<p begin="00:01:13.756" end="00:01:15.387" style="s2">A volume measurement requires</p>
<p begin="00:01:15.387" end="00:01:18.371" style="s2">that you take three measurements,</p>
<p begin="00:01:18.371" end="00:01:21.538" style="s2">the length, the width, and the height.</p>
<p begin="00:01:22.772" end="00:01:25.338" style="s2">Simply tap the corresponding measurement</p>
<p begin="00:01:25.338" end="00:01:28.505" style="s2">and place your calipers on the screen.</p>
<p begin="00:01:31.828" end="00:01:34.611" style="s2">Once all three measurements are completed,</p>
<p begin="00:01:34.611" end="00:01:36.206" style="s2">your volume measurement will appear</p>
<p begin="00:01:36.206" end="00:01:39.874" style="s2">on the upper left side of the screen.</p>
<p begin="00:01:39.874" end="00:01:43.937" style="s2">Be aware that general<br />measurements appear onscreen only,</p>
<p begin="00:01:43.937" end="00:01:46.909" style="s2">and are not in a specific report page.</p>
<p begin="00:01:46.909" end="00:01:49.805" style="s2">Because of this, we recommend<br />that you save the image</p>
<p begin="00:01:49.805" end="00:01:53.740" style="s2">with the measurements<br />before ending the study.</p>
<p begin="00:01:53.740" end="00:01:56.810" style="s2">For more information about<br />measurements and calculations,</p>
<p begin="00:01:56.810" end="00:01:59.227" style="s2">refer to the iViz user guide.</p>
Brightcove ID
5508114154001
https://youtube.com/watch?v=8H8hEC6fLsk