EII rC60 - Fetal Circle of Willis with CPD

EII rC60 - Fetal Circle of Willis with CPD

/sites/default/files/EII%20C60%20OB%20Fetal%20Circle%20of%20Willis%20color%20power.jpg
EII, rC60, Fetal Circle of Willis with Color Power Doppler, OBGYN and L&D
SW Revision
Clinical Specialties
Publication Date
Media Library Type
Compatible Products

TV Uterus with Migrating IUD Sagittal

TV Uterus with Migrating IUD Sagittal

/sites/default/files/TV_Uterus_with_Migrating_IUD_Sagittal.jpg
TV Uterus with Migrating IUD Sagittal
Clinical Specialties
Publication Date
Media Library Type

iViz 9: Cleaning and Disinfecting your iViz System

iViz 9: Cleaning and Disinfecting your iViz System

/sites/default/files/youtube_vKB5Ada5lFc.jpg
SW Revision
Clinical Specialties
Publication Date
Media Library Type
Subtitles
<p begin="00:00:00.543" end="00:00:03.626" style="s2">(light techno music)</p>
<p begin="00:00:08.868" end="00:00:12.118" style="s2">- [Voiceover] Welcome to the help video</p>
<p begin="00:00:14.251" end="00:00:15.377" style="s2">In this video,</p>
<p begin="00:00:15.377" end="00:00:18.190" style="s2">we will walk you though<br />cleaning and disinfecting</p>
<p begin="00:00:18.190" end="00:00:20.773" style="s2">both the system and transducer.</p>
<p begin="00:00:21.658" end="00:00:23.970" style="s2">Let's start with the system.</p>
<p begin="00:00:23.970" end="00:00:25.278" style="s2">Before cleaning,</p>
<p begin="00:00:25.278" end="00:00:28.291" style="s2">you want to make sure to<br />disconnect the transducer</p>
<p begin="00:00:28.291" end="00:00:30.291" style="s2">and turn off the system.</p>
<p begin="00:00:31.272" end="00:00:33.980" style="s2">Clean the exterior surfaces using either</p>
<p begin="00:00:33.980" end="00:00:37.046" style="s2">a soft cloth dampened with a disinfectant,</p>
<p begin="00:00:37.046" end="00:00:38.662" style="s2">or a pre-moistened wipe</p>
<p begin="00:00:38.662" end="00:00:40.916" style="s2">from the list of approved disinfectants</p>
<p begin="00:00:40.916" end="00:00:44.926" style="s2">to remove any particulate<br />matter or body fluids.</p>
<p begin="00:00:44.926" end="00:00:47.518" style="s2">Be sure to apply the solution to the cloth</p>
<p begin="00:00:47.518" end="00:00:50.438" style="s2">rather than applying it<br />directly to the surface</p>
<p begin="00:00:50.438" end="00:00:51.851" style="s2">making sure the solution</p>
<p begin="00:00:51.851" end="00:00:55.507" style="s2">does not get into the connector ports.</p>
<p begin="00:00:55.507" end="00:00:57.675" style="s2">Allow the system to air dry</p>
<p begin="00:00:57.675" end="00:01:01.697" style="s2">or dry it off with a soft, clean cloth.</p>
<p begin="00:01:01.697" end="00:01:05.670" style="s2">Next let's clean and<br />disinfect the transducer.</p>
<p begin="00:01:05.670" end="00:01:09.685" style="s2">Clean the transducer surface<br />using a damp, soft cloth</p>
<p begin="00:01:09.685" end="00:01:14.493" style="s2">to remove any gel, particulate<br />matter, and body fluids.</p>
<p begin="00:01:14.493" end="00:01:17.343" style="s2">Starting from the transducer's scan head,</p>
<p begin="00:01:17.343" end="00:01:20.926" style="s2">wipe in a downward<br />motion towards the cord.</p>
<p begin="00:01:23.032" end="00:01:25.680" style="s2">Once the transducer body is clean,</p>
<p begin="00:01:25.680" end="00:01:28.799" style="s2">use a thin instrument, such as a swab,</p>
<p begin="00:01:28.799" end="00:01:31.365" style="s2">to push the soft damp cleaning cloth</p>
<p begin="00:01:31.365" end="00:01:34.032" style="s2">back and forth through the slot.</p>
<p begin="00:01:40.365" end="00:01:43.596" style="s2">Then rinse or wipe the<br />transducer with water</p>
<p begin="00:01:43.596" end="00:01:46.263" style="s2">to remove the soap or detergent.</p>
<p begin="00:01:48.199" end="00:01:52.594" style="s2">To disinfect the transducer<br />using an approved disinfectant,</p>
<p begin="00:01:52.594" end="00:01:56.775" style="s2">disinfect the slot first<br />and then the transducer.</p>
<p begin="00:01:56.775" end="00:01:59.630" style="s2">If you use the immersion<br />method of disinfecting,</p>
<p begin="00:01:59.630" end="00:02:00.838" style="s2">be sure to follow</p>
<p begin="00:02:00.838" end="00:02:03.631" style="s2">the disinfectant<br />manufacturer's instructions</p>
<p begin="00:02:03.631" end="00:02:05.513" style="s2">and only immerse the transducer</p>
<p begin="00:02:05.513" end="00:02:08.430" style="s2">up to 12 inches from the connector.</p>
<p begin="00:02:09.281" end="00:02:11.669" style="s2">After cleaning and disinfecting,</p>
<p begin="00:02:11.669" end="00:02:16.129" style="s2">check the transducer and<br />cable for any visible damage.</p>
<p begin="00:02:16.129" end="00:02:18.177" style="s2">If you do see any damage,</p>
<p begin="00:02:18.177" end="00:02:22.344" style="s2">discontinue use and contact<br />Fujifilm Sonosite for service.</p>
<p begin="00:02:24.327" end="00:02:25.866" style="s2">For more detailed information</p>
<p begin="00:02:25.866" end="00:02:28.661" style="s2">on cleaning and disinfecting iViz,</p>
<p begin="00:02:28.661" end="00:02:31.661" style="s2">refer to the iViz system user guide.</p>
Brightcove ID
5508136014001
https://youtube.com/watch?v=vKB5Ada5lFc

iViz 8: Taking Measurements

iViz 8: Taking Measurements

/sites/default/files/youtube_8H8hEC6fLsk.jpg
SW Revision
Clinical Specialties
Publication Date
Media Library Type
Subtitles
<p begin="00:00:00.569" end="00:00:04.069" style="s2">(mellow electronic music)</p>
<p begin="00:00:08.981" end="00:00:12.601" style="s2">- [Voiceover] Welcome to the<br />help video Taking Measurements.</p>
<p begin="00:00:12.601" end="00:00:15.374" style="s2">In this video, we will<br />walk you through how to</p>
<p begin="00:00:15.374" end="00:00:20.082" style="s2">take a general measurement with<br />your iViz Ultrasound System.</p>
<p begin="00:00:20.082" end="00:00:22.832" style="s2">While scanning, freeze the image.</p>
<p begin="00:00:25.847" end="00:00:28.723" style="s2">Tap Measurements, and choose either</p>
<p begin="00:00:28.723" end="00:00:31.640" style="s2">the Distance or Volume measurement.</p>
<p begin="00:00:33.073" end="00:00:37.372" style="s2">Drag the active caliper to<br />the start of your measurement.</p>
<p begin="00:00:37.372" end="00:00:41.321" style="s2">Lift your finger to<br />activate the second caliper.</p>
<p begin="00:00:41.321" end="00:00:45.796" style="s2">Slide and place that<br />caliper at your end point.</p>
<p begin="00:00:45.796" end="00:00:50.526" style="s2">The measurement appears on the<br />top left side of the screen.</p>
<p begin="00:00:50.526" end="00:00:54.443" style="s2">To re-position a caliper,<br />just touch and slide.</p>
<p begin="00:00:55.754" end="00:00:59.497" style="s2">To add an additional caliper,<br />tap the measurement type</p>
<p begin="00:00:59.497" end="00:01:02.747" style="s2">and place those calipers on the screen.</p>
<p begin="00:01:04.308" end="00:01:08.494" style="s2">To delete a caliper, select<br />the caliper you want to delete</p>
<p begin="00:01:08.494" end="00:01:10.411" style="s2">and then tap the red X.</p>
<p begin="00:01:13.756" end="00:01:15.387" style="s2">A volume measurement requires</p>
<p begin="00:01:15.387" end="00:01:18.371" style="s2">that you take three measurements,</p>
<p begin="00:01:18.371" end="00:01:21.538" style="s2">the length, the width, and the height.</p>
<p begin="00:01:22.772" end="00:01:25.338" style="s2">Simply tap the corresponding measurement</p>
<p begin="00:01:25.338" end="00:01:28.505" style="s2">and place your calipers on the screen.</p>
<p begin="00:01:31.828" end="00:01:34.611" style="s2">Once all three measurements are completed,</p>
<p begin="00:01:34.611" end="00:01:36.206" style="s2">your volume measurement will appear</p>
<p begin="00:01:36.206" end="00:01:39.874" style="s2">on the upper left side of the screen.</p>
<p begin="00:01:39.874" end="00:01:43.937" style="s2">Be aware that general<br />measurements appear onscreen only,</p>
<p begin="00:01:43.937" end="00:01:46.909" style="s2">and are not in a specific report page.</p>
<p begin="00:01:46.909" end="00:01:49.805" style="s2">Because of this, we recommend<br />that you save the image</p>
<p begin="00:01:49.805" end="00:01:53.740" style="s2">with the measurements<br />before ending the study.</p>
<p begin="00:01:53.740" end="00:01:56.810" style="s2">For more information about<br />measurements and calculations,</p>
<p begin="00:01:56.810" end="00:01:59.227" style="s2">refer to the iViz user guide.</p>
Brightcove ID
5508114154001
https://youtube.com/watch?v=8H8hEC6fLsk

iViz 7: Annotating an Image

iViz 7: Annotating an Image

/sites/default/files/youtube_MRz8V7sf9kw.jpg
SW Revision
Clinical Specialties
Publication Date
Media Library Type
Subtitles
<p begin="00:00:08.737" end="00:00:12.602" style="s2">- [Voiceover] Welcome to the<br />help video Annotating an Image.</p>
<p begin="00:00:12.602" end="00:00:15.128" style="s2">In this video, we will walk you through</p>
<p begin="00:00:15.128" end="00:00:17.874" style="s2">how to create a custom annotation label</p>
<p begin="00:00:17.874" end="00:00:19.828" style="s2">and then annotate an image</p>
<p begin="00:00:19.828" end="00:00:23.300" style="s2">using your iViz ultrasound system.</p>
<p begin="00:00:23.300" end="00:00:27.910" style="s2">To create custom labels,<br />tap the iViz settings icon</p>
<p begin="00:00:27.910" end="00:00:29.160" style="s2">and tap labels.</p>
<p begin="00:00:30.462" end="00:00:32.862" style="s2">Select an exam type.</p>
<p begin="00:00:32.862" end="00:00:36.592" style="s2">There you will find a list<br />of the exams default labels.</p>
<p begin="00:00:36.592" end="00:00:41.108" style="s2">From here, you can also add<br />up to ten custom labels.</p>
<p begin="00:00:41.108" end="00:00:43.129" style="s2">To create a custom label,</p>
<p begin="00:00:43.129" end="00:00:46.177" style="s2">type the label name in the Add field.</p>
<p begin="00:00:46.177" end="00:00:48.967" style="s2">If you want to create more than one label,</p>
<p begin="00:00:48.967" end="00:00:51.951" style="s2">separate the label names with a comma,</p>
<p begin="00:00:51.951" end="00:00:53.034" style="s2">then tap Add.</p>
<p begin="00:00:54.539" end="00:00:59.108" style="s2">Note that you cannot add<br />spaces to the label names.</p>
<p begin="00:00:59.108" end="00:01:02.626" style="s2">You can also create custom<br />labels while annotating</p>
<p begin="00:01:02.626" end="00:01:06.767" style="s2">and they will be added to the<br />exam type you're currently in.</p>
<p begin="00:01:06.767" end="00:01:08.946" style="s2">To annotate on the current image,</p>
<p begin="00:01:08.946" end="00:01:12.029" style="s2">freeze the image and tap Text Labels.</p>
<p begin="00:01:14.261" end="00:01:17.729" style="s2">Select a label from the<br />list and drag the label</p>
<p begin="00:01:17.729" end="00:01:21.018" style="s2">to where you want to<br />place it on the screen.</p>
<p begin="00:01:21.018" end="00:01:23.851" style="s2">To add an arrow, tap + Arrow.</p>
<p begin="00:01:25.205" end="00:01:28.062" style="s2">If you want, rotate the arrow by grabbing</p>
<p begin="00:01:28.062" end="00:01:31.645" style="s2">the blue orientation<br />arrow and rotating it.</p>
<p begin="00:01:32.575" end="00:01:36.514" style="s2">Then place the arrow where you want it.</p>
<p begin="00:01:36.514" end="00:01:38.436" style="s2">To create a custom label,</p>
<p begin="00:01:38.436" end="00:01:42.103" style="s2">type the label name in<br />the enter text field.</p>
<p begin="00:01:50.584" end="00:01:52.917" style="s2">If you want to delete a custom label,</p>
<p begin="00:01:52.917" end="00:01:55.975" style="s2">you must go back to the<br />label setting screen</p>
<p begin="00:01:55.975" end="00:01:57.642" style="s2">and delete it there.</p>
<p begin="00:02:12.223" end="00:02:16.354" style="s2">To annotate a saved image,<br />slide the tool drawer up</p>
<p begin="00:02:16.354" end="00:02:18.187" style="s2">to access Text Labels.</p>
<p begin="00:02:19.054" end="00:02:21.909" style="s2">For more information<br />about annotating images,</p>
<p begin="00:02:21.909" end="00:02:24.409" style="s2">refer to the iViz User Guide.</p>
Brightcove ID
5508120204001
https://youtube.com/watch?v=MRz8V7sf9kw

iViz 5: Performing an Exam

iViz 5: Performing an Exam

/sites/default/files/youtube_8tTpiFeRdDI.jpg
SW Revision
Clinical Specialties
Publication Date
Media Library Type
Subtitles
<p begin="00:00:00.626" end="00:00:03.709" style="s2">(light guitar music)</p>
<p begin="00:00:08.813" end="00:00:12.897" style="s2">- [Voiceover] Welcome to the<br />help video, Performing an Exam.</p>
<p begin="00:00:12.897" end="00:00:17.207" style="s2">In this video, we will explain<br />how to select an exam type,</p>
<p begin="00:00:17.207" end="00:00:21.163" style="s2">adjust parameters, such<br />as depth, overall gain,</p>
<p begin="00:00:21.163" end="00:00:24.482" style="s2">near and far gain, optimization,</p>
<p begin="00:00:24.482" end="00:00:27.482" style="s2">and change the scan mode using iViz.</p>
<p begin="00:00:28.617" end="00:00:31.459" style="s2">To select an exam type<br />while you're scanning,</p>
<p begin="00:00:31.459" end="00:00:34.226" style="s2">tap the Exam Type drop down menu</p>
<p begin="00:00:34.226" end="00:00:37.167" style="s2">and select a different exam type.</p>
<p begin="00:00:37.167" end="00:00:39.729" style="s2">The control wheel options are specific</p>
<p begin="00:00:39.729" end="00:00:42.070" style="s2">to the mode that you're in.</p>
<p begin="00:00:42.070" end="00:00:44.840" style="s2">You can adjust the depth by tapping Depth</p>
<p begin="00:00:44.840" end="00:00:47.187" style="s2">on the control wheel.</p>
<p begin="00:00:47.187" end="00:00:50.324" style="s2">By tapping the plus or minus icons,</p>
<p begin="00:00:50.324" end="00:00:53.617" style="s2">you can increase or<br />decrease the scanning depth,</p>
<p begin="00:00:53.617" end="00:00:57.284" style="s2">or tap one of the dots<br />for a specific depth.</p>
<p begin="00:01:00.807" end="00:01:03.534" style="s2">The overall gain is adjusted by tapping</p>
<p begin="00:01:03.534" end="00:01:06.350" style="s2">Overall Gain on the control wheel,</p>
<p begin="00:01:06.350" end="00:01:10.438" style="s2">and then moving the blue<br />dot up and down the slider,</p>
<p begin="00:01:10.438" end="00:01:14.021" style="s2">or by tapping a specific<br />spot on the wheel.</p>
<p begin="00:01:17.460" end="00:01:20.265" style="s2">Your near and fair gain can be adjusted</p>
<p begin="00:01:20.265" end="00:01:23.015" style="s2">by toggling between near and far.</p>
<p begin="00:01:23.949" end="00:01:28.116" style="s2">To set the gain, move the blue<br />dot up and down the slider.</p>
<p begin="00:01:29.584" end="00:01:32.186" style="s2">To adjust your imaging frequencies,</p>
<p begin="00:01:32.186" end="00:01:35.168" style="s2">slide the control wheel to O-P-T,</p>
<p begin="00:01:35.168" end="00:01:37.799" style="s2">which stands for optimization.</p>
<p begin="00:01:37.799" end="00:01:41.966" style="s2">This allows you to change<br />between RES, PEN, or T-H-I.</p>
<p begin="00:01:44.129" end="00:01:46.597" style="s2">You can adjust other 2D options,</p>
<p begin="00:01:46.597" end="00:01:49.501" style="s2">such as dynamic range and orientation,</p>
<p begin="00:01:49.501" end="00:01:52.584" style="s2">by sliding the wheel with your thumb.</p>
<p begin="00:01:53.835" end="00:01:56.549" style="s2">2D is the default scan mode.</p>
<p begin="00:01:56.549" end="00:02:00.719" style="s2">To change to M mode, press<br />and hold the 2D button</p>
<p begin="00:02:00.719" end="00:02:02.469" style="s2">on the control wheel.</p>
<p begin="00:02:03.380" end="00:02:07.395" style="s2">Slide the M line to the<br />desired spot on the screen,</p>
<p begin="00:02:07.395" end="00:02:10.062" style="s2">and then tap Update to activate.</p>
<p begin="00:02:11.122" end="00:02:14.789" style="s2">Tap Update again to<br />return to live scanning.</p>
<p begin="00:02:16.066" end="00:02:20.149" style="s2">Press and hold the M button<br />to toggle back to 2D.</p>
<p begin="00:02:21.835" end="00:02:25.903" style="s2">Tap Color on the control<br />wheel while in 2D.</p>
<p begin="00:02:25.903" end="00:02:29.205" style="s2">From here, you can adjust<br />other color parameters,</p>
<p begin="00:02:29.205" end="00:02:30.622" style="s2">such as box size,</p>
<p begin="00:02:35.156" end="00:02:35.989" style="s2">placement,</p>
<p begin="00:02:40.535" end="00:02:42.535" style="s2">color gain, scale, flow,</p>
<p begin="00:02:47.352" end="00:02:51.200" style="s2">as well as switch between<br />color velocity doppler</p>
<p begin="00:02:51.200" end="00:02:53.788" style="s2">and color power doppler.</p>
<p begin="00:02:53.788" end="00:02:56.538" style="s2">Color doppler toggles on and off.</p>
<p begin="00:02:57.907" end="00:03:00.114" style="s2">For more information about exams,</p>
<p begin="00:03:00.114" end="00:03:03.112" style="s2">refer to the iViz user guide.</p>
<p begin="00:03:03.112" end="00:03:06.195" style="s2">(light guitar music)</p>
Brightcove ID
5508114719001
https://youtube.com/watch?v=8tTpiFeRdDI

iViz 4: Creating a New Patient Study

iViz 4: Creating a New Patient Study

/sites/default/files/youtube_2InyEeulSOw.jpg
SW Revision
Clinical Specialties
Publication Date
Media Library Type
Subtitles
<p begin="00:00:07.929" end="00:00:10.513" region="r2" style="s2">
- [Voiceover] Welcome to the help video,</p>
<p begin="00:00:10.513" end="00:00:13.572" region="r3" style="s2">
Creating a New Patient Study.</p>
<p begin="00:00:13.572" end="00:00:16.375" region="r4" style="s2">
In this video, we will<br />
show you the different ways</p>
<p begin="00:00:16.375" end="00:00:20.213" region="r5" style="s2">
you can start a new<br />
Patient study using iViz.</p>
<p begin="00:00:20.213" end="00:00:23.680" region="r6" style="s2">
There are three ways to<br />
start a new Patient study.</p>
<p begin="00:00:23.680" end="00:00:26.823" region="r7" style="s2">
You can select a Patient<br />
from the Scheudled list</p>
<p begin="00:00:26.823" end="00:00:30.279" region="r2" style="s2">
or enter a new study from a search menu.</p>
<p begin="00:00:30.279" end="00:00:32.713" region="r8" style="s2">
You can also start a new Patient study</p>
<p begin="00:00:32.713" end="00:00:35.147" region="r9" style="s2">
after completing a scan.</p>
<p begin="00:00:35.147" end="00:00:37.995" region="r7" style="s2">
To start a new study<br />
from the Scheduled list,</p>
<p begin="00:00:37.995" end="00:00:42.162" region="r4" style="s2">
from the Home screen, tap<br />
Patient, and then Schedule.</p>
<p begin="00:00:45.546" end="00:00:49.960" region="r10" style="s2">
You can press the Refresh button<br />
to update the Patient list.</p>
<p begin="00:00:49.960" end="00:00:52.396" region="r11" style="s2">
Select a Patient from the list.</p>
<p begin="00:00:52.396" end="00:00:56.449" region="r12" style="s2">
The Patient's information<br />
automatically populates the form.</p>
<p begin="00:00:56.449" end="00:00:58.398" region="r13" style="s2">
Notice that you can also start</p>
<p begin="00:00:58.398" end="00:01:02.075" region="r7" style="s2">
a new Patient study from<br />
this screen as well.</p>
<p begin="00:01:02.075" end="00:01:05.158" region="r14" style="s2">
To start scanning, tap the scan icon.</p>
<p begin="00:01:06.571" end="00:01:09.667" region="r15" style="s2">
To start a new study from the Search menu,</p>
<p begin="00:01:09.667" end="00:01:12.500" region="r16" style="s2">
from the Home screen, tap Paitent.</p>
<p begin="00:01:14.758" end="00:01:17.675" region="r17" style="s2">
From the Search tab, tap New Study.</p>
<p begin="00:01:20.364" end="00:01:24.072" region="r18" style="s2">
Notice that iViz prompts you<br />
to close the current study</p>
<p begin="00:01:24.072" end="00:01:26.916" region="r19" style="s2">
before starting a new one.</p>
<p begin="00:01:26.916" end="00:01:28.733" region="r9" style="s2">
From the Patient Screen,</p>
<p begin="00:01:28.733" end="00:01:32.900" region="r18" style="s2">
type the Patient information<br />
in the appropriate fields.</p>
<p begin="00:01:37.541" end="00:01:41.208" region="r20" style="s2">
To close the keyboard,<br />
press the down arrow.</p>
<p begin="00:01:43.036" end="00:01:45.369" region="r16" style="s2">
Scroll down to make you've entered</p>
<p begin="00:01:45.369" end="00:01:47.869" region="r13" style="s2">
all the necessary information.</p>
<p begin="00:01:50.661" end="00:01:54.828" region="r4" style="s2">
Tap Save, or the Scan icon,<br />
to save the Patient form.</p>
<p begin="00:01:58.340" end="00:02:02.101" region="r5" style="s2">
And finally, you can also<br />
enter Patient information</p>
<p begin="00:02:02.101" end="00:02:04.568" region="r13" style="s2">
after you've completed a scan,</p>
<p begin="00:02:04.568" end="00:02:06.588" region="r21" style="s2">
by tapping the Patient field</p>
<p begin="00:02:06.588" end="00:02:09.338" region="r22" style="s2">
and then tapping the Patient tab.</p>
<p begin="00:02:16.017" end="00:02:19.400" region="r23" style="s2">
For more information about<br />
managing Patients and Studies,</p>
<p begin="00:02:19.400" end="00:02:21.817" region="r3" style="s2">
refer to the iViz User Guide.</p>
Brightcove ID
5508105698001
https://youtube.com/watch?v=2InyEeulSOw